Cylinder Force Calculator
Work out the push and pull force of a hydraulic or pneumatic cylinder from its bore, rod diameter and pressure, with the speed from a flow rate.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Cylinder Force Calculator does
This cylinder force calculator will work out the push and pull force of a hydraulic or pneumatic cylinder from its bore, rod diameter and pressure, with the speed from a flow rate. Fill in all 6 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for sizing a cylinder for a known load. If you need the other side of this job, there is also a specific heat calculator.
How to use it
- Enter the bore and rod diameters in millimetres.
- Enter the working pressure in bar — typically 6 to 10 for air, 100 to 250 for hydraulics.
- Add a flow rate to see the extend and retract speeds.
- Check the pull force, not just the push: it is always lower.
How it works
Cylinder force is pressure times area, and the whole of the engineering is in which area. Extending, the pressure acts on the full bore face. Retracting, the rod occupies part of that face, so the pressure acts on an annulus — the bore area minus the rod area — and the force is correspondingly lower. A 50 mm bore cylinder with a 25 mm rod pulls at 75 per cent of what it pushes, and that asymmetry is the commonest sizing mistake: a cylinder chosen on its push rating and then asked to pull the same load comes up short.
The same asymmetry shows up in speed, in the opposite direction. A given flow rate has to fill the bore volume to extend and only the annulus volume to retract, so the cylinder retracts faster than it extends from the same supply. On the example above it retracts about a third faster. If a machine cycle needs equal times in both directions, that has to be designed in with flow controls or a different cylinder — it does not happen by itself.
The pressure range tells you which technology you are looking at, and they behave differently in ways that matter beyond the arithmetic. Hydraulics run at 100 to 250 bar or more with an effectively incompressible fluid, so a cylinder holds its position under load and moves at a speed determined by the flow. Pneumatics run at 6 to 10 bar with air, which compresses — so a pneumatic cylinder is springy under load, will not hold a precise position against a changing force, and accelerates hard at the start of a stroke. That is why pneumatics suit end-to-end motion and hydraulics suit controlled positioning under load.
Two things this calculation deliberately does not cover, and both can decide a design. It gives static force at the stated pressure; real output under movement is lower, because pressure drops across valves and hoses with flow. And a long cylinder pushing is a column in compression, which can buckle at a load well below its force rating. As a rough guide, once the stroke exceeds about ten times the rod diameter, the rod needs checking against buckling rather than against force, and the manufacturer’s stroke-versus-load chart is the right reference.
When to use it
- Sizing a cylinder for a known load.
- Checking the pull force of a cylinder chosen for its push.
- Working out cycle speeds from a pump or compressor flow.
- Finding the fluid volume a cycle consumes, to size a pump or reservoir.
- Comparing a pneumatic and a hydraulic solution for the same job.
Common mistakes to avoid
- Sizing on push force and then using the cylinder to pull. Pull is always lower.
- Expecting equal extend and retract speeds from one flow rate.
- Using the rated pressure as the working pressure. Pressure drops across valves and hoses under flow.
- Ignoring buckling on a long stroke in compression.
- Expecting a pneumatic cylinder to hold position precisely under a varying load.
Frequently asked questions
How do you calculate hydraulic cylinder force?
Pressure times the piston area. At 160 bar on a 50 mm bore that is 16 MPa times 1963.5 mm², which is 31.4 kN pushing. Retracting uses the bore area minus the rod area, so it is lower.
Why is the pull force lower than the push force?
Because the rod occupies part of the piston face on the retract side, so the pressure acts on a smaller annular area. With a rod half the bore diameter, pull is 75 per cent of push.
Is the formula different for pneumatic cylinders?
No — force is still pressure times area. What differs is the pressure range and the behaviour: air compresses, so a pneumatic cylinder is springy under load and cannot hold a precise position against a varying force.
Why does my cylinder retract faster than it extends?
The same flow has to fill the full bore volume to extend and only the annulus to retract. Less volume at the same flow means more speed. Flow controls are how you equalise it if the cycle needs that.
What pressure should I use?
The working pressure the circuit actually delivers at the cylinder, not the pump’s rating. Pressure drops across valves, fittings and hoses under flow, and the difference is often substantial.