Insulation Calculator
Work out the R-value and U-value of an insulation layer, and the thickness needed to reach a target performance.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Insulation Calculator does
The insulation calculator on this page will work out the R-value and U-value of an insulation layer, and the thickness needed to reach a target performance. Fill in all 5 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for working out how thick an insulation layer needs to be. More utilities in this area are collected on FreeToolsWorld.org.
How to use it
- Enter the insulation thickness and its thermal conductivity from the product data sheet.
- Enter the R-value of the rest of the construction — plasterboard, masonry, surface resistances.
- Set the target U-value you need to reach.
- Read the resulting U-value and the thickness the target requires.
How it works
R-value measures resistance to heat flow and adds up across layers; U-value measures how readily heat passes through and is the reciprocal of the total R. Higher R is better, lower U is better, and conflating the two is the commonest confusion in the subject.
The American R-value is a different number for the same performance, because it uses imperial units. An R-value of 1 in SI equals about 5.68 in US units, so "R-30 loft insulation" in the United States is about R-5.3 in SI terms. Always check which system a quoted figure uses.
Thermal bridging is the thing this calculation ignores and the thing that most often spoils real performance. Timber studs, steel fixings, joists and junctions all conduct around the insulation, and a wall with 15% timber fraction performs measurably worse than its insulation alone suggests. A proper U-value calculation accounts for this; a simple layer sum does not.
Target U-values are set by building regulations and differ by country, by element and by whether the work is new build or a retrofit. The 0.18 default here is in the general area of current practice for walls in a cool climate, not a figure to design to.
When to use it
- Working out how thick an insulation layer needs to be.
- Comparing insulation materials on performance per millimetre.
- Converting between R-value and U-value.
- Estimating heat loss through an element.
Common mistakes to avoid
- Mixing SI and US R-values, which differ by a factor of 5.68.
- Ignoring thermal bridging, which makes the real U-value worse than calculated.
- Using a generic λ instead of the declared value for the actual product.
Frequently asked questions
What is the difference between R-value and U-value?
R-value is thermal resistance and adds across layers — higher is better. U-value is thermal transmittance, the reciprocal of total R — lower is better.
How thick should loft insulation be?
It depends on the target U-value and the material. To reach 0.16 W/(m²·K) with mineral wool at λ 0.040 you need around 250 mm. Current regulations in cool climates typically ask for 270 to 300 mm of mineral wool.
Is US R-30 the same as SI R-30?
No. US R-values are in ft²·°F·h/BTU and SI in m²·K/W. US R-30 is about SI R-5.3. The factor is 5.678.