Pipe Flow Calculator

Convert between pipe diameter, flow velocity and volumetric flow rate, and check the velocity against normal design limits.

mm
L/s
m
mm
Drawn copper 0.0015, commercial steel 0.045, cast iron 0.26.
Cross-sectional area 1963.5 mm²
Flow velocity 1.528 m/s
v = Q ÷ A · hf = f (L/D) v² ÷ 2g
Flow rate 10.8 m³/h
Flow rate in US gallons per minute 47.55 gpm
Reynolds number for water at 20 °C 76,089
Estimated friction head loss 2.271 m
v = Q ÷ A · hf = f (L/D) v² ÷ 2g
Velocity check Within the usual 0.5-2.5 m/s design range

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Pipe Flow Calculator does

This pipe flow calculator will convert between pipe diameter, flow velocity and volumetric flow rate, and check the velocity against normal design limits. Fill in all 4 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for sizing a pipe run for a given flow. Next to this one sits our speed of sound calculator.

How to use it

  1. Enter the pipe inside diameter in millimetres — not the nominal size.
  2. Enter the flow rate in litres per second.
  3. Enter the straight pipe length and the roughness for the material.
  4. Check the velocity against the design range and read the friction loss.

How it works

Velocity is flow rate over cross-sectional area, and because area goes with the square of diameter, a modest increase in pipe size cuts velocity sharply. Doubling the diameter quarters the velocity for the same flow.

The head loss figure uses the Darcy-Weisbach equation with the Swamee-Jain explicit approximation to the Colebrook friction factor, which is accurate to about 1% over the normal range of Reynolds numbers and relative roughness. It is the friction loss in straight pipe only: bends, valves, tees and fittings add their own losses, often more than the straight run on a short system.

The 0.5 to 2.5 m/s range is a general design convention for water, balancing pumping cost against pipe cost, noise and erosion. It is not a rule, and specific applications — fire mains, suction lines, slurry — use their own limits.

When to use it

  • Sizing a pipe run for a given flow.
  • Checking whether an existing pipe is undersized.
  • Estimating friction losses for pump selection.
  • Converting between flow rate units.

Common mistakes to avoid

  • Using nominal pipe size instead of actual internal diameter — they differ substantially.
  • Ignoring fitting losses, which can exceed the straight-pipe loss on a short system.
  • Treating this as a complete pump sizing. Static lift and fitting losses must be added.

Frequently asked questions

What is a good water velocity in a pipe?

Typically 0.5 to 2.5 m/s. Below that, sediment settles; above it, noise, erosion and pumping cost rise sharply. Specific applications have their own limits.

Does this include losses from bends and valves?

No. It covers straight pipe friction only. Fittings are usually accounted for with equivalent lengths or K-factors added on top.

Why is nominal pipe size not the internal diameter?

Nominal sizes are historical designations rather than measurements. A nominal 50 mm steel pipe has an internal diameter near 52.5 mm; schedule and material both change it. Use the real bore from a pipe table.