Radiation Dose Converter
Convert radiation dose between sieverts, rem, gray and rad, with the distinction between absorbed and effective dose.
1 Millisievert = 100 mrem Both units are exactly defined, so this conversion is exact.
| Millisievert | Millirem |
|---|---|
| 1 mSv | 100 mrem |
| 2 mSv | 200 mrem |
| 5 mSv | 500 mrem |
| 10 mSv | 1,000 mrem |
| 25 mSv | 2,500 mrem |
| 50 mSv | 5,000 mrem |
| 100 mSv | 10,000 mrem |
| 500 mSv | 50,000 mrem |
| 1,000 mSv | 100,000 mrem |
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Radiation Dose Converter does
This radiation dose converter will convert radiation dose between sieverts, rem, gray and rad, with the distinction between absorbed and effective dose. It covers 8 units and converts in both directions, so you can start from whichever figure you already have. It is most often used for converting a medical imaging dose between sieverts and rem. Next to this one sits our magnetic field converter.
How to use it
- Enter the dose in the unit you have.
- Pick the target unit.
- Check whether your figure is absorbed dose (gray, rad) or equivalent dose (sievert, rem) — for alpha or neutron radiation these differ by a weighting factor.
How it works
The gray and the sievert measure different things and the conversion between them is not a constant. The gray is absorbed dose: energy deposited per kilogram of tissue, a purely physical quantity. The sievert is equivalent dose: absorbed dose multiplied by a radiation weighting factor that reflects how much biological damage that type of radiation causes. For X-rays, gamma rays and beta particles the factor is 1, so the numbers coincide. For alpha particles it is 20, and for neutrons it ranges from 5 to 20 depending on energy.
That is why this converter treats them as the same scale: it is correct for the photon and beta radiation that dominate medical and background exposure, and wrong for alpha and neutron exposure, where the weighting factor has to be applied explicitly. Anyone working with alpha or neutron sources needs the factor, not a converter.
Reference doses in millisieverts: a chest X-ray about 0.02, a dental X-ray 0.005, a mammogram 0.4, a head CT 2, an abdominal CT 8 to 10, a transatlantic flight 0.08, and natural background radiation 2 to 3 per year globally with wide regional variation — parts of Iran, India and Brazil exceed 10 from natural sources alone.
Occupational limits under the current international recommendations are 20 mSv per year averaged over five years for radiation workers, with 50 mSv in any single year. The public limit is 1 mSv per year above background.
This converter handles units. It does not assess risk, which depends on the dose rate, the tissue exposed, the type of radiation and the individual — and which is a matter for a qualified health physicist or clinician rather than a web page.
Millisievert to Millirem reference table
| Millisievert | Millirem |
|---|---|
| 1 mSv | 100 mrem |
| 2 mSv | 200 mrem |
| 5 mSv | 500 mrem |
| 10 mSv | 1,000 mrem |
| 25 mSv | 2,500 mrem |
| 50 mSv | 5,000 mrem |
| 100 mSv | 10,000 mrem |
| 250 mSv | 25,000 mrem |
| 500 mSv | 50,000 mrem |
| 1,000 mSv | 100,000 mrem |
All supported units and their factors
| Unit | Symbol | Base units per unit | Notes |
|---|---|---|---|
| Sievert | Sv | 1 | approx. SI unit of equivalent and effective dose — absorbed dose weighted for biological effect. |
| Millisievert | mSv | 0.001 | exact The practical unit for medical and occupational doses. |
| Microsievert | µSv | 0.000001 | exact Used for background radiation and single X-rays. |
| Rem | rem | 0.01 | exact The older unit, still used in the United States. 1 Sv = 100 rem. |
| Millirem | mrem | 0.00001 | exact |
| Gray | Gy | 1 | approx. SI unit of ABSORBED dose — joules per kilogram. Numerically equal to the sievert only for photon and beta radiation. |
| Milligray | mGy | 0.001 | exact |
| Rad | rad | 0.01 | exact The older absorbed dose unit. 1 Gy = 100 rad. |
When to use it
- Converting a medical imaging dose between sieverts and rem.
- Converting an older American dose figure to SI units.
- Comparing a reported dose against published reference figures.
- Reading a dosimeter in unfamiliar units.
Common mistakes to avoid
- Treating gray and sievert as interchangeable for alpha or neutron radiation, where they differ by a factor of up to 20.
- Confusing dose with dose rate — sieverts against sieverts per hour.
- Mixing millisieverts and microsieverts, a thousandfold error.
Frequently asked questions
How many rem is one sievert?
Exactly 100 rem. One millisievert is 100 millirem.
What is the difference between gray and sievert?
Gray is absorbed energy per kilogram; sievert is that weighted for biological effect. They match for X-rays, gamma and beta radiation but differ by a factor of up to 20 for alpha and neutron radiation.
How much radiation is a chest X-ray?
About 0.02 mSv, roughly equivalent to three days of natural background radiation. An abdominal CT is around 8 to 10 mSv, which is several years of background.