Radioactivity Converter

Convert radioactivity between becquerels and curies, the activity units that measure decays rather than dose.

1 Megabecquerel = 0.027027027027 mCi Both units are exactly defined, so this conversion is exact.

Quick reference for the pair you have selected.
MegabecquerelMillicurie
1 MBq0.027027027 mCi
2 MBq0.054054054 mCi
5 MBq0.13513514 mCi
10 MBq0.27027027 mCi
25 MBq0.67567568 mCi
50 MBq1.3513514 mCi
100 MBq2.7027027 mCi
500 MBq13.513514 mCi
1,000 MBq27.027027 mCi

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Radioactivity Converter does

Use this radioactivity converter to convert radioactivity between becquerels and curies, the activity units that measure decays rather than dose. It covers 12 units and converts in both directions, so you can start from whichever figure you already have. It is most often used for converting a radiopharmaceutical activity between MBq and mCi. We run a second free tools site as well — FreeToolStation.org.

How to use it

  1. Enter the activity in the unit you have.
  2. Pick the target unit.
  3. Note that activity is not dose — converting between them needs the isotope and the exposure conditions.

How it works

Activity measures how many nuclei decay per second in a sample. It says nothing on its own about the hazard, because that depends on what kind of radiation the decay emits, how energetic it is, whether the source is inside or outside the body, and which tissue is exposed. A becquerel of an alpha emitter lodged in the lung is a completely different proposition from a becquerel of a weak beta emitter in a sealed container.

The becquerel is an inconveniently small unit — one decay per second — which is why practical figures are in megabecquerels or gigabecquerels. A typical nuclear medicine injection is a few hundred MBq. A banana contains about 15 Bq from its natural potassium-40.

The curie was originally defined as the activity of one gram of radium-226, and was later fixed at exactly 3.7 × 10¹⁰ Bq to keep it stable when the radium figure was refined. It remains in use in the United States, where radon in homes is measured in picocuries per litre — the EPA action level of 4 pCi/L is 148 Bq/m³.

Activity and dose are different quantities and the sievert page covers the dose side. Converting activity to dose requires knowing the isotope, the decay mode, the exposure geometry and the exposure time, which is a health physics calculation rather than a unit conversion.

Megabecquerel to Millicurie reference table

Values computed from the exact factor 1 MBq = 0.027027027027 mCi. Use the converter above for any other value.
MegabecquerelMillicurie
1 MBq 0.027027027 mCi
2 MBq 0.054054054 mCi
5 MBq 0.13513514 mCi
10 MBq 0.27027027 mCi
25 MBq 0.67567568 mCi
50 MBq 1.3513514 mCi
100 MBq 2.7027027 mCi
250 MBq 6.7567568 mCi
500 MBq 13.513514 mCi
1,000 MBq 27.027027 mCi

All supported units and their factors

Factors are relative to the base unit, Becquerel. Units marked exact are defined by international agreement rather than measured.
UnitSymbolBase units per unitNotes
Becquerel Bq 1 approx. SI unit of activity: one nuclear decay per second.
Kilobecquerel kBq 1000 exact
Megabecquerel MBq 1000000 exact The practical unit for medical radiopharmaceuticals.
Gigabecquerel GBq 1000000000 exact
Terabecquerel TBq 1000000000000 exact
Curie Ci 37000000000 exact Originally the activity of one gram of radium-226. Now defined as exactly 3.7 × 10¹⁰ Bq.
Millicurie mCi 37000000 exact
Microcurie µCi 37000 exact
Nanocurie nCi 37 exact
Picocurie pCi 0.037 exact Used for radon measurement in the United States — pCi per litre of air.
Disintegration per second dps 1 exact Identical to the becquerel.
Disintegration per minute dpm 0.016666666666666666 exact

When to use it

  • Converting a radiopharmaceutical activity between MBq and mCi.
  • Converting a radon measurement between pCi/L and Bq/m³.
  • Reading an older American activity figure.
  • Converting a source activity for a laboratory record.

Common mistakes to avoid

  • Treating activity as a measure of hazard. The hazard depends on the radiation type, energy and exposure route.
  • Confusing becquerels with sieverts — activity and dose are different quantities.
  • Mixing curie prefixes, where the steps are factors of a thousand on an already large base unit.

Frequently asked questions

How many becquerels in a curie?

Exactly 3.7 × 10¹⁰, which is 37 gigabecquerels. The figure was originally the activity of one gram of radium-226.

What is the difference between becquerels and sieverts?

Becquerels measure decays per second in a source. Sieverts measure the biological dose received. Converting between them needs the isotope, the radiation type and the exposure conditions.

What is the radon action level?

The US EPA uses 4 pCi/L, which is 148 Bq/m³. The WHO reference level is 100 Bq/m³, with 300 Bq/m³ as the maximum where that is not achievable.