Roof Pitch Calculator
Convert between roof pitch, angle in degrees and percentage slope, and find the rafter length and roof area.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Roof Pitch Calculator does
This roof pitch calculator will convert between roof pitch, angle in degrees and percentage slope, and find the rafter length and roof area. Fill in all 4 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for converting a roof pitch ratio into degrees. People using this often want the raised bed soil calculator next.
How to use it
- Enter the rise and run of your pitch — 6 and 12 for a 6:12 roof.
- Enter the building span and the roof length along the ridge.
- Read the angle, the rafter length and the total surface area.
- Check the suitability note against the minimum pitch your chosen covering specifies.
How it works
Roof pitch gets expressed three different ways and they are easy to confuse. The ratio form — 6:12 — is rise over run, almost always with a run of 12 in imperial practice, so a 6:12 roof rises six inches for every twelve horizontal. The angle form converts that to degrees with an arctangent: 6:12 is 26.57°. The percentage form is simply rise divided by run as a percentage, so 6:12 is 50% — and the common error is to read a 100% slope as vertical when it is actually 45°.
The rafter length is the hypotenuse of the triangle formed by half the span and the ridge height, which is why it is always longer than the horizontal distance it covers. That difference is the area factor, and it is the number that matters when ordering materials: a 6:12 roof has a surface area 1.118 times its flat footprint, so a 96 m² footprint needs 107 m² of covering. At 45° the factor is 1.414, and ordering to the footprint area would leave you 29% short.
Minimum pitch is a product specification rather than a general rule, and getting it wrong causes leaks that no amount of good workmanship fixes. Plain clay tiles generally want 35° or more, slates around 25°, interlocking concrete tiles sometimes as low as 12.5°, and standing-seam metal lower still. Below about 10° you are into membrane territory — single-ply, built-up felt or liquid applied — because discrete overlapping units cannot reliably shed water that is barely moving downhill. Always check the specific product's published minimum, and note that it often rises when the rafter run is long or the site is exposed.
Two practical notes. The rafter length here is the geometric length from wall plate to ridge centre and does not include the eaves overhang, the birdsmouth cut or the ridge-board deduction, all of which a carpenter adds or subtracts on site. And building regulations in most places constrain roof height and sometimes pitch for reasons unrelated to water — overlooking, street character, conservation areas — so a pitch that works technically may still need permission.
When to use it
- Converting a roof pitch ratio into degrees.
- Working out rafter lengths for a new roof or an extension.
- Calculating roof area for ordering tiles, felt or insulation.
- Checking whether a pitch is steep enough for a particular covering.
Common mistakes to avoid
- Ordering materials to the flat footprint area rather than the sloped surface area.
- Reading a percentage slope as an angle. A 100% slope is 45°, not vertical.
- Choosing a covering without checking its published minimum pitch, which varies hugely between products.
Frequently asked questions
What is a 6:12 roof pitch in degrees?
26.57°. The angle is arctan(6/12) = arctan(0.5), and the slope is 50% — which is a different number from the angle and frequently confused with it.
How much extra area does a pitched roof have?
The factor is √(1 + (rise/run)²). A 6:12 pitch gives 1.118, so 11.8% more than the footprint; a 45° roof gives 1.414, or 41.4% more. Ordering to the footprint leaves you short by exactly that margin.
What is the minimum pitch for roof tiles?
It depends entirely on the product. Plain clay tiles usually want 35° or more, slates around 25°, and some interlocking concrete tiles are rated to 12.5°. Below roughly 10° you need a continuous membrane rather than discrete tiles. Always check the manufacturer's figure for the specific product.