Stair Stringer Calculator

Work out the stringer board length, the notch cuts and the minimum board width for a flight, with the throat depth that decides whether it is strong enough.

mm
mm
mm
The width of the timber you are cutting from.
mm
Stringer length along the slope 4049 mm
stringer length = (risers − 1) × √(rise per step² + going²) · throat = board width − (rise × going) ÷ √(rise² + going²)
Board length to buy 4200 mm
Rise per step 185.7 mm
Total horizontal run 3250 mm
Pitch (nosing line) 36.61 °
Throat depth left after notching 250.9 mm
Minimum board width for a 90 mm throat 240 mm
Check Throat depth of 250.9 mm is above the 90 mm rule of thumb. Remember to drop the bottom riser cut by the tread thickness (22 mm), or the first step ends up that much taller than the rest.

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Stair Stringer Calculator does

This stair stringer calculator will work out the stringer board length, the notch cuts and the minimum board width for a flight, with the throat depth that decides whether it is strong enough. Fill in all 5 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for working out the board length to buy before cutting a flight. If you need the other side of this job, there is also a flooring calculator.

How to use it

  1. Enter the finished floor-to-floor rise and how many risers you are using.
  2. Enter the going per tread and the width of the board you will cut from.
  3. Check the throat depth before cutting — it is what decides the strength.

How it works

A stringer is the sawtooth board a flight sits on, and two numbers decide whether it works. The first is its length along the slope, which is the hypotenuse of the total rise and the total run — straightforward once you know that the run has one fewer going than there are risers, because the top riser lands on the upper floor and that floor provides its own tread. Forgetting this makes the run one tread too long and the stringer too shallow for the opening.

The second number is the throat: the perpendicular distance left from the inside corner of a notch to the back edge of the board. This is the timber actually carrying the load, and it is always less than the board width because each notch cuts into the board at an angle. The depth it cuts is the altitude of the notch triangle — rise times going, divided by the step hypotenuse — so a 186 mm rise on a 250 mm going eats 149 mm whatever board you use. On a 400 mm board that leaves 251 mm; on a 200 mm board it leaves 51 mm, which is a row of weak points rather than a beam. The usual minimum is about 90 mm, and the fix below it is a wider board or a cleated construction rather than hoping.

One number here deliberately disagrees with most calculators. The length is worked out as the number of treads times the step hypotenuse, which is the slope the board genuinely lies on. The familiar √(total rise² + total run²) mixes a fourteen-riser rise with a thirteen-tread run and so returns the diagonal of the bounding box — about 113 mm longer on the example above. That makes it a safe figure to buy timber against, which is why it persists, but it is not the board length, and the pitch taken from it is two degrees steeper than the stair really is. Pitch here is the angle of the nosing line, rise per step against going: the angle a framing square is set to and the one regulations cap.

One practical detail catches almost everyone on their first flight. The bottom riser cut must be shortened by the thickness of the tread material, because at the bottom the stringer sits on the floor while every tread above it sits on a notch. Skip it and the first step is one tread thicker than the rest — which is both uncomfortable and, in most building regulations, a failure, since riser heights have to be uniform within a few millimetres.

When to use it

  • Working out the board length to buy before cutting a flight.
  • Checking a board is wide enough once the notches are taken out.
  • Checking a pitch against the 42° limit before committing to a rise and going.
  • Setting out notch marks with a framing square from the rise and going.
  • Sanity-checking a stair design against the comfort rule before committing.

Common mistakes to avoid

  • Using the same number of goings as risers. The run has one fewer, because the top riser lands on the floor above.
  • Cutting the bottom riser full height. It must be reduced by the tread thickness or the first step is too tall.
  • Ignoring the throat. A board that looks wide enough can be left with under 90 mm of timber once notched.
  • Measuring from an unfinished floor. Rise is finished floor to finished floor, including any screed or covering still to go on.

Frequently asked questions

How long a board do I need?

The board-to-buy figure, which is the slope length plus 150 mm for the end cuts, rounded up to the next 50 mm. Add more if the bottom is cut to sit against a kicker.

What is throat depth and why does it matter?

The timber left behind a notch, measured perpendicular to the board edge. It carries the load. The notch cuts in by rise × going ÷ √(rise² + going²), so a 186 mm rise on a 250 mm going takes 149 mm off whatever board you start with. Below about 90 mm remaining, the stringer is weak at every notch regardless of how wide the board looked.

Why is the bottom riser cut shorter?

Because the stringer sits directly on the floor there, while every tread above sits on a notch. Reducing it by the tread thickness keeps all the risers equal.

Do these figures meet building regulations?

They are the geometry, not the rules. Maximum rise, minimum going, headroom and handrail requirements vary by country and by whether the stair is domestic — check your local regulations before building.