Pipe Volume Calculator
Work out the volume inside a pipe from its bore and length, with the water weight and the fill time at a given flow rate.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Pipe Volume Calculator does
This pipe volume calculator will work out the volume inside a pipe from its bore and length, with the water weight and the fill time at a given flow rate. Fill in all 4 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for working out how much water a heating or plumbing run holds before draining it. Next to this one sits our flooring calculator.
How to use it
- Enter the internal diameter — the bore, not the outside measurement.
- Enter the length of the run.
- Set a fill percentage for a partly-full pipe, and a flow rate for the fill time.
How it works
The volume inside a pipe is the area of its bore times its length, and the only thing that regularly goes wrong is which diameter gets used. Pipe is very often named by its outside diameter or by a nominal size that matches neither measurement: 15 mm copper has a bore near 13.6 mm, 22 mm copper is about 20.2 mm, and "half-inch" steel pipe has an outside diameter of 21.3 mm. Since volume goes as the square of the radius, using 22 instead of 20.2 overstates the contents by 19%.
That squaring is worth a feel for generally. Doubling the bore quadruples the volume, so one 22 mm pipe holds the same as four 11 mm ones. It is also why a small bore restricts flow far more than its size suggests, and why going up one pipe size makes a much larger difference to a slow run than it looks like it should.
The water weight matters more than people expect on a long or elevated run. A 22 mm pipe holds about 0.35 litres per metre, so a 50-metre run is around 17 kg of water — enough to matter for the fixings on a ceiling run, and enough that draining a system changes what the supports are carrying. Water is taken here as 0.9982 kg per litre, its density at 20 °C; the round 1 kg per litre everyone quotes is the figure at 4 °C.
When to use it
- Working out how much water a heating or plumbing run holds before draining it.
- Sizing the inhibitor or antifreeze dose for a system, which is set by volume.
- Estimating how long a line takes to fill or flush at a known flow rate.
- Checking the weight a long horizontal run adds to its supports.
Common mistakes to avoid
- Using the outside diameter. Pipe is named by it; volume depends on the bore, and the gap is often 10% or more.
- Forgetting that volume goes as the radius squared. A 10% error in diameter is a 21% error in volume.
- Mixing units. Bore in millimetres, length in metres — that is what this tool expects.
- Treating nominal pipe size as a measurement. "Half-inch" pipe is neither half an inch outside nor inside.
Frequently asked questions
Should I use the inside or outside diameter?
Inside — the bore. Pipe is usually sold by outside or nominal diameter, and using that overstates the volume because volume depends on the square of the radius.
How much water is in a metre of 15 mm pipe?
About 0.145 litres, using a 13.6 mm bore. A metre of 22 mm pipe holds about 0.32 litres at a 20.2 mm bore.
How do I handle a partly full pipe?
The fill percentage here scales the volume linearly, which is right for a pipe running full along part of its length. A horizontal pipe part-filled along its whole length is a circular-segment problem and does not scale linearly.
Does the water weight figure include the pipe?
No, only the water. Add the pipe itself if you are checking what a support carries.