Pump Flow Rate and Power Calculator
Work out the hydraulic power a pump delivers from flow and head, then the shaft and electrical power it draws once pump and motor efficiency are allowed for.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Pump Flow Rate and Power Calculator does
This pump flow rate and power calculator will work out the hydraulic power a pump delivers from flow and head, then the shaft and electrical power it draws once pump and motor efficiency are allowed for. Fill in all 8 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for sizing a motor for a pump duty of a given flow and head. If you need the other side of this job, there is also a watts, amps and volts calculator.
How to use it
- Enter the flow rate and pick its unit.
- Enter the total head — static lift plus friction losses plus any outlet pressure.
- Set the fluid density if you are not pumping cold water.
- Enter pump and motor efficiency to get the shaft and electrical power.
How it works
Hydraulic power is ρgQH: density times gravity times volumetric flow times head. For water at 998.2 kg/m³ flowing at 180 L/min against 24 m of head, that is 998.2 × 9.80665 × 0.003 × 24 = 704.8 W. This is the useful power — the rate at which energy is actually being given to the water — and it is the only figure in this calculation that is pure physics.
Everything after that is a division by an efficiency, and the three numbers always rise in the same order. At 65% pump efficiency, 704.8 W of water power needs 1,084.3 W at the shaft; at 85% motor efficiency that shaft power needs 1,275.7 W from the supply, or 1.276 kW. The overall efficiency is the product of the two, 55.25%, which means about 45% of the electricity is becoming heat in the motor windings and in turbulence inside the pump casing.
Head is the input that gets calculations wrong, far more often than efficiency. Total head is not the vertical rise. It is the static lift, plus the friction losses through every metre of pipe and every bend, valve and fitting, plus any pressure required at the outlet. Friction loss rises roughly with the square of the flow, so doubling the flow through the same pipe roughly quadruples the friction component — which is why a pump sized on static lift alone delivers far less than expected, and why going up a pipe size is often cheaper than going up a pump size.
Pump efficiency is not a constant either. A centrifugal pump has a best efficiency point, and it falls away on both sides of it: the same pump at half its design flow might manage 45% where it made 70%. Published figures are at the best point. Small domestic pumps commonly run 40% to 55% overall, while large well-matched industrial units reach into the 80s. If a pump is oversized and throttled back with a valve, the throttling itself is pure loss, and a variable-speed drive instead will usually pay for itself.
Energy per cubic metre is the number worth carrying around for comparisons, because it is independent of how long the pump runs. 1.276 kW moving 180 L/min is 0.118 kWh per cubic metre at 24 m of head — and because head and energy are proportional, the same pump against 48 m would use roughly twice that. Water utilities quote figures in this form, and at a few pence or cents per cubic metre it is a useful check on whether a pumping arrangement is sensible.
When to use it
- Sizing a motor for a pump duty of a given flow and head.
- Checking a pump manufacturer’s power figure against the physics.
- Working out the running cost of an irrigation, pool or borehole pump.
- Comparing two pumps on energy per cubic metre rather than on rated power.
- Seeing how much power is lost to pump and motor inefficiency.
Common mistakes to avoid
- Using the vertical lift as the total head and ignoring friction losses and outlet pressure.
- Taking a manufacturer’s peak efficiency as the efficiency at your operating point.
- Forgetting that friction loss rises with the square of the flow.
- Throttling an oversized pump with a valve instead of slowing it down.
- Using water density for a fluid that is not water. Seawater and oils change the answer.
Frequently asked questions
What is the formula for pump power?
Hydraulic power is density × gravity × flow × head, with flow in cubic metres per second and head in metres. Divide by pump efficiency for shaft power, and again by motor efficiency for electrical power drawn.
What is total head?
Static lift plus friction losses plus any pressure needed at the outlet, all expressed in metres of fluid. It is not the vertical rise alone, and on a long or narrow pipe run the friction component can exceed the lift.
What pump efficiency should I assume?
If you have a pump curve, read it at your actual duty point. Failing that, 40% to 55% for small domestic pumps, 60% to 75% for mid-size centrifugal units at a sensible duty, and into the 80s only for large well-matched installations.
Why does my pump use more power than this says?
Usually because the real head is higher than assumed, or the pump is running away from its best efficiency point. Motor standby and control losses, and a power factor below one on the supply side, also add to what the meter sees.
How does head affect running cost?
Proportionally. Double the head and you double the energy per cubic metre pumped, all else equal. That is why reducing friction losses — larger pipe, fewer fittings, less restrictive valves — directly reduces the electricity bill.