Watts, Amps and Volts Calculator

Convert between watts, amps and volts in either direction, with the power-factor correction that AC circuits need and DC ones do not.

W
A
V
Only used for the AC options. Motors 0.7–0.9; heaters and incandescent lamps 1.
Result 2300
W = A × V · single-phase AC: W = A × V × PF · three-phase: W = A × V × √3 × PF
Which quantity Watts
Formula applied W = A × V
In kilowatts 2.3 kW
Equivalent resistance 23 Ω
Worth knowing With no power factor, watts are simply amps times volts. That is exact for DC and for purely resistive AC loads such as heaters and filament lamps.

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Watts, Amps and Volts Calculator does

This watts, amps and volts calculator will convert between watts, amps and volts in either direction, with the power-factor correction that AC circuits need and DC ones do not. Fill in all 6 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for working out the current an appliance will draw from its wattage. A related tool on this site is the specific heat calculator.

How to use it

  1. Choose which quantity you want.
  2. Fill in the two you know, and pick DC or AC.
  3. For AC, set the power factor — 1 for a heater, 0.7–0.9 for a motor.

How it works

For direct current, and for alternating current driving a purely resistive load, power really is just amps times volts. A 2,300 W heater on a 230 V supply draws 10 A, and the arithmetic needs nothing else. That covers heaters, filament lamps, kettles and immersion elements — anything that turns electricity straight into heat.

Everything with a motor, a transformer or a switched-mode power supply behaves differently, and that is what the power factor is for. In those loads the current and voltage waveforms do not peak together, so some of the current flowing does no useful work. Real power in watts is amps × volts × power factor; amps × volts alone gives apparent power in volt-amps. The distinction is not academic: the cable and the breaker have to carry the apparent current, while the meter bills the real power, which is why a motor rated 1 kW can draw 1.3 kVA.

Three-phase adds a factor of √3, about 1.732, and the most common error with it is using the wrong voltage. The √3 formula assumes line-to-line voltage — 400 V in most of Europe, 415 V in the UK, 208 V in North American commercial supplies — which is the figure normally quoted on a nameplate. Using the line-to-neutral voltage instead and keeping the √3 overstates the power by 73%.

When to use it

  • Working out the current an appliance will draw from its wattage.
  • Checking whether a load fits inside a plug fuse or a circuit rating.
  • Sizing a generator or an inverter from the equipment it has to run.
  • Converting a three-phase motor rating into line current.

Common mistakes to avoid

  • Leaving the power factor at 1 for a motor. That understates the current by 10 to 30%.
  • Confusing watts with volt-amps. Cables and breakers care about VA; the bill is in watts.
  • Using phase voltage with the √3 three-phase formula. The formula expects line-to-line.
  • Sizing a cable from the arithmetic alone. Current rating depends on cable type, grouping, insulation and ambient temperature, which no calculator sees.

Frequently asked questions

How many amps is 1000 watts?

It depends on the voltage. At 230 V it is 4.35 A; at 120 V it is 8.33 A; at 12 V it is 83.3 A. Power alone does not determine current.

What power factor should I use?

1 for heaters and filament lamps. 0.8 to 0.9 for most motors, 0.9 to 0.95 for a modern switched-mode supply with correction. A nameplate usually states it.

What is the difference between watts and VA?

Watts is the power actually doing work; VA is voltage times current regardless of phase. For a resistive load they are equal, otherwise VA is larger and is what the wiring must carry.

Can I use this to size cable?

It gives you the current, which is the starting point — but cable rating depends on installation method, grouping, insulation and ambient temperature. For anything fixed or high-current, ask an electrician.