Stair Calculator
Work out step rise and going from a total floor-to-floor height, and check the result against the usual comfort rules.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Stair Calculator does
This stair calculator will work out step rise and going from a total floor-to-floor height, and check the result against the usual comfort rules. Fill in all 4 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for laying out a new staircase. The companion to this one is our board foot calculator.
How to use it
- Measure the total height from finished floor to finished floor, not floor to ceiling.
- Enter your preferred step rise — around 190 mm is typical for a domestic stair.
- Enter the going, the horizontal depth of each tread.
- Check the resulting pitch and the 2R + G figure against the comfort ranges.
How it works
Every riser in a flight must be identical. A single step a few millimetres different from its neighbours is the classic trip hazard, because people climb stairs by rhythm rather than by looking. That is why the rise is derived by dividing the total height by a whole number of steps rather than set directly.
The 2R + G rule, usually attributed to François Blondel in 1675, says that twice the rise plus the going should fall between about 600 and 660 mm. It encodes the natural relationship between step height and stride length, and stairs that violate it feel wrong to walk even when they meet the dimensional limits.
Building regulations set binding limits on maximum rise, minimum going, maximum pitch, minimum headroom and handrail requirements, and they differ by country and by whether the stair is domestic, public or a loft access. This tool helps you lay out a flight; it does not tell you whether that flight complies where you are. Check the applicable regulations before building.
Headroom is the constraint people discover late. Two metres clear measured vertically above the pitch line is a common minimum, and it is what forces a stair into a different position or a different shape more often than the run does.
When to use it
- Laying out a new staircase.
- Checking whether an existing stair meets the comfort rule.
- Working out how much floor space a stair will take.
- Comparing layouts to fit a stair into a given opening.
Common mistakes to avoid
- Measuring floor to ceiling instead of finished floor to finished floor.
- Allowing one step to differ in height from the rest.
- Treating the comfort check as a regulatory check. They are not the same thing.
Frequently asked questions
What is a comfortable stair rise?
Around 175 to 200 mm for a domestic stair, with the going between 230 and 280 mm. The 2R + G figure should land between 600 and 660 mm.
How many steps for a 2.6 metre floor height?
Fourteen risers at 185.7 mm each, or thirteen at 200. Fourteen is usually the more comfortable of the two.
Does this check building regulations?
No. It helps you lay out a flight and flags the common comfort rule. Maximum rise, minimum going, pitch, headroom and handrails are all set by regulations that differ by country and by building type.