Viscosity Converter
Convert dynamic viscosity between pascal-seconds, poise and centipoise, with the kinematic units kept separate.
1 Centipoise = 0.001 Pa·s The most common practical unit. Water at 20 °C is almost exactly 1 cP, which is why the unit survives.
| Centipoise | Pascal second |
|---|---|
| 1 cP | 0.001 Pa·s |
| 2 cP | 0.002 Pa·s |
| 5 cP | 0.005 Pa·s |
| 10 cP | 0.01 Pa·s |
| 25 cP | 0.025 Pa·s |
| 50 cP | 0.05 Pa·s |
| 100 cP | 0.1 Pa·s |
| 500 cP | 0.5 Pa·s |
| 1,000 cP | 1 Pa·s |
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Viscosity Converter does
The viscosity converter on this page will convert dynamic viscosity between pascal-seconds, poise and centipoise, with the kinematic units kept separate. It covers 7 units and converts in both directions, so you can start from whichever figure you already have. It is most often used for converting a lubricant or fluid specification between units. Companion tools to this one live on FreeToolsWorld.org.
How to use it
- Enter the viscosity in the unit you have.
- Pick the target unit.
- Check whether your source figure is dynamic or kinematic viscosity — this converter handles dynamic only.
How it works
Dynamic viscosity measures a fluid's resistance to shear and is what the SI pascal second describes. Kinematic viscosity is dynamic viscosity divided by density, measured in square metres per second or centistokes, and it is a different quantity — the two cannot be converted without knowing the fluid's density. Conflating them is the commonest error in the subject.
The centipoise survives because water at 20 °C has a dynamic viscosity of almost exactly 1 cP, which makes the unit intuitive: a fluid of 50 cP is fifty times as viscous as water. One centipoise is also exactly one millipascal second, so the two are numerically identical and used interchangeably.
Viscosity is strongly temperature-dependent and the dependence is steep. Water halves in viscosity between 20 °C and 55 °C. Engine oil changes by more than an order of magnitude between a cold start and operating temperature, which is the entire reason multigrade oils exist — the "10W-40" notation describes behaviour at two different temperatures because one number cannot capture it.
Reference values in centipoise at room temperature: water 1, blood about 4, olive oil 80, honey 2,000 to 10,000, and glass at room temperature somewhere above 10²⁰ — which is why the claim that old window glass has visibly flowed is not true on a scale of centuries.
Centipoise to Pascal second reference table
| Centipoise | Pascal second |
|---|---|
| 1 cP | 0.001 Pa·s |
| 2 cP | 0.002 Pa·s |
| 5 cP | 0.005 Pa·s |
| 10 cP | 0.01 Pa·s |
| 25 cP | 0.025 Pa·s |
| 50 cP | 0.05 Pa·s |
| 100 cP | 0.1 Pa·s |
| 250 cP | 0.25 Pa·s |
| 500 cP | 0.5 Pa·s |
| 1,000 cP | 1 Pa·s |
All supported units and their factors
| Unit | Symbol | Base units per unit | Notes |
|---|---|---|---|
| Pascal second | Pa·s | 1 | approx. The SI unit of dynamic viscosity. Also written N·s/m². |
| Millipascal second | mPa·s | 0.001 | exact Numerically identical to the centipoise, which is why both are used interchangeably. |
| Poise | P | 0.1 | exact CGS unit, named after Jean Léonard Marie Poiseuille. |
| Centipoise | cP | 0.001 | exact The most common practical unit. Water at 20 °C is almost exactly 1 cP, which is why the unit survives. |
| Kilogram per metre second | kg/(m·s) | 1 | exact Dimensionally identical to the pascal second. |
| Pound-force second per square foot | lbf·s/ft² | 47.880259 | approx. Imperial engineering unit. |
| Reyn | reyn | 6894.757 | approx. Pound-force second per square inch, used in American lubrication engineering. |
When to use it
- Converting a lubricant or fluid specification between units.
- Converting centipoise to pascal seconds for a calculation.
- Reading an older imperial viscosity figure.
- Checking a fluid property from a data sheet.
Common mistakes to avoid
- Converting a kinematic viscosity with dynamic factors. They are different quantities related by density.
- Using a viscosity figure without its temperature, which can change it by an order of magnitude.
- Treating the poise and the centipoise as interchangeable — they differ by a factor of a hundred.
Frequently asked questions
What is the viscosity of water?
About 1.002 mPa·s at 20 °C, which is 1.002 centipoise. The near-exact value of 1 cP is why the unit is still used.
What is the difference between dynamic and kinematic viscosity?
Kinematic is dynamic divided by density. Dynamic is in pascal seconds, kinematic in square metres per second or centistokes. Converting between them requires the density.
Why does oil viscosity have two numbers?
Because viscosity changes by more than an order of magnitude with temperature. A 10W-40 rating describes cold-start behaviour and operating-temperature behaviour separately, since one figure cannot capture both.