Decking Calculator

Work out how many decking boards, joists and fixings a deck needs, including the gaps between boards.

m
m
mm
mm
m
mm
%
Deck area 17.5 m²
Rows of boards 24
rows = deck width ÷ (board width + gap) · joists = length ÷ spacing + 1
Boards to buy 53
rows = deck width ÷ (board width + gap) · joists = length ÷ spacing + 1
Linear metres of board 132 m
Joists needed 14
rows = deck width ÷ (board width + gap) · joists = length ÷ spacing + 1
Linear metres of joist 49 m
Screws, two per board per joist 672

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Decking Calculator does

This decking calculator will work out how many decking boards, joists and fixings a deck needs, including the gaps between boards. Fill in all 7 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for ordering decking boards and joists for a new deck. People using this often want the brick calculator next.

How to use it

  1. Enter the deck dimensions.
  2. Enter the board width and the gap you intend to leave.
  3. Enter the board length your supplier stocks.
  4. Set the joist spacing for your board type and layout.

How it works

The gap between boards is structural, not cosmetic. Timber decking swells across its width when wet, and boards laid tight will buckle or split their fixings. Five to six millimetres is conventional for timber fitted dry; composite boards have their own specified gap, usually larger, and also need an end gap because they expand lengthways with temperature in a way timber does not.

Joist spacing of 400 mm centres suits most timber decking laid square to the joists. Boards laid diagonally need closer spacing — typically 300 mm — because the unsupported span across the diagonal is longer. Composite decking usually specifies tighter centres again; follow the manufacturer, because a bouncy composite deck cannot be fixed afterwards.

This counts the deck surface and its joists. It does not size the bearers, posts or foundations, which depend on the deck height, the ground, and in many places on building regulations. A raised deck is a structure, not a surface.

When to use it

  • Ordering decking boards and joists for a new deck.
  • Costing a deck before committing.
  • Checking a supplier's material list.
  • Working out fixing quantities.

Common mistakes to avoid

  • Laying boards with no gap, so they buckle when wet.
  • Using 400 mm joist centres for a diagonal or composite deck that needs closer.
  • Treating this as a structural design. Raised decks need proper bearer and post sizing.

Frequently asked questions

What gap should I leave between decking boards?

Five to six millimetres for timber fitted in dry conditions — less if the boards are already wet, since they will shrink. Composite boards have their own specified gap, usually larger.

How far apart should deck joists be?

400 mm centres for timber boards laid square to the joists, 300 mm for a diagonal layout. Composite decking often specifies closer; check the manufacturer.

How many screws do I need?

Two per board at every joist crossing. A 3.5 metre wide deck with 24 board rows and 14 joists needs around 672 screws.

Related tools

See all home & diy →