Solar Panel Calculator

Estimate the yearly output of a solar array from its size and your location's peak sun hours, with a realistic system loss factor.

W
Roughly 2.5-3.5 in northern Europe, 4-5 in the southern US, 5-6 in the Gulf and much of Australia.
%
Inverter, wiring, soiling, temperature and shading together.
kWh
Array size 5.04 kWp
yearly kWh = kWp × peak sun hours × (1 − losses) × 365
Average daily output 12.9 kWh
Yearly output 4709 kWh
yearly kWh = kWp × peak sun hours × (1 − losses) × 365
Share of your usage covered 117.7 %
yearly kWh = kWp × peak sun hours × (1 − losses) × 365
Value at your tariff 1318.63
Panels needed to cover all usage 10.2
Approximate roof area needed 24 m²

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Solar Panel Calculator does

Use this solar panel calculator to estimate the yearly output of a solar array from its size and your location's peak sun hours, with a realistic system loss factor. Fill in all 6 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for sizing a rooftop array against your electricity use. More utilities in this area are collected on FreeToolStation.org.

How to use it

  1. Enter the panel wattage and how many you plan to install.
  2. Enter the peak sun hours for your location.
  3. Adjust the loss percentage if you know your system — 20% is a reasonable default.
  4. Enter your yearly consumption to see what share the array would cover.

How it works

Peak sun hours is not daylight hours. It is the number of hours of 1000 W/m² irradiance that would deliver the same total energy as the real day — so a long overcast day might be two peak sun hours and a short clear winter day one. The figure is location-specific and the single largest factor in the result; look it up for your actual location rather than using a regional average.

The 20% default loss covers inverter efficiency, DC and AC wiring, soiling, module mismatch and the fact that panels produce less when hot. Panel ratings are measured at 25 °C cell temperature, and a roof-mounted panel in summer runs far above that — typically losing 10 to 15% of output to temperature alone.

Yearly output is an annual average and the seasonal distribution is severe at high latitudes: a UK array produces several times more in June than in December. Covering 100% of annual usage does not mean being self-sufficient, because the surplus arrives in summer and the demand in winter.

The roof area figure assumes about 2 m² per panel, which suits most residential 400-450 W modules, plus nothing for access or spacing.

When to use it

  • Sizing a rooftop array against your electricity use.
  • Sanity-checking an installer's output estimate.
  • Comparing two array sizes.
  • Estimating the value of generation at your tariff.

Common mistakes to avoid

  • Confusing peak sun hours with hours of daylight.
  • Ignoring shading, which affects far more output than its area suggests on a string inverter.
  • Treating annual coverage as self-sufficiency. Generation and demand are out of phase by season.

Frequently asked questions

How many solar panels do I need?

Divide your yearly consumption by the yearly output per panel. A 420 W panel at 3.2 peak sun hours with 20% losses makes about 392 kWh a year, so a 4000 kWh household needs around ten panels to match annual usage.

What are peak sun hours?

The equivalent hours of full 1000 W/m² sunshine that deliver the same daily energy as the real day. It bundles daylight length, sun angle and cloud into one number, and it is location-specific.

Why is actual output lower than the panel rating?

Panel ratings are measured in laboratory conditions at 25 °C. Real arrays lose output to heat, inverter conversion, wiring, dust and shading — typically 15 to 25% in total.