Water Pressure Calculator

Convert between water head in metres and pressure in bar, psi and kilopascals, with the pressure loss along a pipe run.

m
bar
psi
°C
Density changes slightly with temperature.
m
Leave at zero to skip.
mm
L/min
Pressure 1.7621 bar
pressure = ρgh · 1 bar ≈ 10.2 m of head ≈ 14.5 psi · friction by Hazen-Williams with C = 130
In psi 25.5568 psi
In kilopascals 176.208 kPa
Equivalent head 18 m
Equivalent head 59.055 ft
Flow velocity in the pipe 0.5261 m/s
Pressure lost to friction 0 bar
Pressure at the far end 1.7621 bar
Worth knowing Water pressure from height is ρgh: 18 m of head gives 1.7621 bar, or 25.56 psi. The useful rules of thumb are 1 bar per 10.2 m and 1 psi per 2.31 ft — and note that the width of the tank is irrelevant. Only the height matters. This is static pressure with a correction for friction, not a full hydraulic calculation. It assumes a full pipe, steady flow and no fittings — and fittings matter: a single elbow is worth roughly a metre of straight pipe, and a partly closed valve can be worth far more than the whole run. Water density is taken at 20°C (998.23 kg/m³). The common 1000 kg/m³ is only accurate near 4°C, and the difference is around 0.4% at domestic hot water temperatures.

Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.

What the Water Pressure Calculator does

The water pressure calculator on this page will convert between water head in metres and pressure in bar, psi and kilopascals, with the pressure loss along a pipe run. Fill in all 8 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for converting a tank height into pressure at a tap or shower. Companion tools to this one live on FreeToolsWorld.org.

How to use it

  1. Choose whether you know the head, the pressure in bar, or the pressure in psi.
  2. Enter the value and the water temperature.
  3. For a pipe run, enter the length, bore and flow rate to see the friction loss.

How it works

Pressure from a column of water is density times gravity times height — ρgh — and the thing that surprises people is what is missing from it. The width of the tank does not appear. A 20 metre column in a drinking straw produces exactly the same pressure at its base as a 20 metre column in a reservoir. Only the vertical distance between the water surface and the outlet matters, which is why a loft tank gives the same pressure at a tap whether it holds fifty litres or five hundred — what the volume changes is how long that pressure lasts, not what it is.

The useful conversions are worth memorising: one bar is about 10.2 metres of head, and one psi is about 2.31 feet. So a tank three metres above a shower head gives roughly 0.3 bar, which is why gravity-fed showers on the floor below a loft tank are weak, and why a pump is the usual fix. Mains pressure in a typical supply is 2 to 4 bar, equivalent to 20 to 40 metres of head, which is far more than any domestic tank arrangement can produce.

Static pressure is only half the story once water is moving. Friction in the pipe costs pressure, and the relationship with bore is dramatic: the loss goes roughly as the bore to the power of minus five, so going from 15 mm to 22 mm pipe cuts the friction loss by about eighty per cent at the same flow rate. That is why a long run in undersized pipe gives poor flow at the far end even with good pressure at the source, and why increasing the pipe size is usually more effective than adding a pump.

Velocity is worth watching alongside pressure. Around 2 metres per second is the usual comfortable maximum for domestic pipework. Above that, pipes become audible, water hammer gets worse when valves close quickly, and erosion at bends accelerates over years. If a calculation produces a high velocity, the pipe is too small for the flow regardless of whether the pressure works out.

Two things this does not do. It assumes a full pipe with steady flow and no fittings, and fittings are not negligible — a single elbow is worth roughly a metre of straight pipe in equivalent length, a tee more, and a partly closed valve can dominate an entire run. And it uses Hazen-Williams with a coefficient of 130, which suits copper and plastic domestic pipe carrying water at ordinary temperatures; it is an empirical formula and outside that range it is the wrong tool.

When to use it

  • Converting a tank height into pressure at a tap or shower.
  • Checking whether gravity feed will give enough pressure.
  • Working out the pressure loss along a long pipe run.
  • Deciding whether to increase pipe size or add a pump.
  • Converting between bar, psi and metres of head.

Common mistakes to avoid

  • Thinking tank volume affects pressure. Only the height does.
  • Ignoring friction on a long run, which can cost more than the head provides.
  • Using 1000 kg/m³ for hot water, which is about 0.4 per cent out.
  • Sizing pipe without checking velocity. Above about 2 m/s it gets noisy.
  • Omitting fittings. An elbow is worth about a metre of pipe, and a throttled valve far more.

Frequently asked questions

How much pressure does 1 metre of water give?

About 0.098 bar, or 1.42 psi. The rules of thumb are 1 bar per 10.2 metres and 1 psi per 2.31 feet of head.

Does the size of the tank affect water pressure?

No. Pressure depends only on the vertical height of water above the outlet. A bigger tank at the same height gives the same pressure for longer, not higher pressure.

Why is my shower weak even though the tank is full?

Almost always insufficient head. A tank three metres above the shower gives about 0.3 bar, which is low. Friction in a long or narrow pipe run makes it worse. A pump or larger pipe is the fix; a fuller tank is not.

How much does pipe size affect flow?

A great deal. Friction loss varies roughly as the bore to the power of minus five, so going from 15 mm to 22 mm cuts the loss by around 80 per cent at the same flow. Increasing pipe size is often more effective than adding pressure.

What is a safe water velocity in a pipe?

Up to about 2 m/s for domestic pipework. Above that, pipes become noisy, water hammer worsens, and erosion at bends accelerates over time.

Related tools