Generator Sizing Calculator
Work out the generator size you need from your running watts and the starting surge, which is what actually decides it.
Everything you type here is processed on your own device. No input is sent to a server, logged, or stored.
What the Generator Sizing Calculator does
Use this generator sizing calculator to work out the generator size you need from your running watts and the starting surge, which is what actually decides it. Fill in all 6 fields and the result updates as you type — there is no Calculate button to press and no page reload. It is most often used for choosing a generator for power cuts. More utilities in this area are collected on FreeToolStation.org.
How to use it
- Add up the running watts of everything you intend to run at once.
- Find the item with the biggest starting surge — usually a motor — and enter its running and starting watts.
- Leave some headroom. Running a generator at its limit continuously shortens its life.
- If the site is high above sea level, enter the altitude to see the derated output.
How it works
Two numbers decide generator size, and only one of them is obvious. The running load is the sum of what everything draws continuously. The starting surge is the extra that a motor demands for the first second or two as it spins up — commonly two to three times its running figure, and sometimes more for a compressor under load. A fridge drawing 150 watts running may need 600 at the instant the compressor kicks in.
The calculation people get wrong is adding every item’s starting watts together. That assumes the fridge, the pump and the air conditioner all start at the same instant, which essentially never happens — and it sizes the generator at nearly double what you need, which is expensive, heavier, thirstier and runs badly under-loaded. The honest figure is the full running load plus the single largest surge, because that is the worst case: everything running and the biggest motor choosing that moment to start.
Headroom is worth paying for separately. A generator run at its continuous rating all day is working as hard as it can, which shortens its life, burns more fuel per watt and leaves nothing for the thing you forgot. Twenty per cent is a reasonable allowance. At the other extreme, running a diesel generator at a very light load for long periods causes its own problems — wet stacking, where unburnt fuel glazes the cylinders — so a set vastly oversized for its load is not a safe choice either.
Two specification details. Generators are advertised with two ratings: a continuous or running figure and a higher peak or surge figure, and it is the running rating that must cover your calculated size. And anything rated in kVA rather than kW is quoting apparent power — real power is kVA times the power factor, so a 7.35 kVA set at 0.8 delivers about 5.9 kW. Altitude matters too: engines lose roughly three per cent of output per 300 metres, so a set sized at sea level will not deliver the same on a mountain site.
Finally, the part that is not arithmetic. Connecting a generator to house wiring requires a transfer switch and, nearly everywhere, a qualified electrician. Plugging a generator into a socket to back-feed the house energises the supply line outside and has killed utility workers. It is illegal in most jurisdictions for exactly that reason.
When to use it
- Choosing a generator for power cuts.
- Sizing a set for a caravan, boat, workshop or site.
- Checking whether a generator you already own will start a particular motor.
- Converting between a kW requirement and a kVA nameplate.
- Allowing for altitude on a high-elevation site.
Common mistakes to avoid
- Adding every item’s starting watts. Motors start one at a time, and this oversizes by nearly double.
- Sizing to the peak rating rather than the continuous one.
- Leaving no headroom, so the set runs flat out whenever everything is on.
- Ignoring altitude on a high site, where output drops measurably.
- Back-feeding through a socket instead of fitting a transfer switch. This kills line workers.
Frequently asked questions
What size generator do I need for a house?
It depends entirely on what you intend to run. Add the running watts of everything you need at once, then add the largest single starting surge. Essentials only — fridge, lights, boiler, a few sockets — usually land between 3 and 6 kW; whole-house with air conditioning or electric heating is much more.
Should I add the starting watts of everything?
No. That assumes every motor starts simultaneously, which does not happen, and it roughly doubles the size you buy. Use the running total plus the single biggest surge.
What is the difference between running watts and starting watts?
Running watts is the continuous draw. Starting watts is the brief surge a motor needs to spin up, typically two to three times its running figure. Generators quote both, and your continuous requirement must fit the running rating.
How do I convert kVA to kW?
Multiply kVA by the power factor. At 0.8, a 10 kVA generator delivers 8 kW of real power. Domestic appliances are rated in watts, so the kW figure is the one to match.
Can I plug a generator into a wall socket to power the house?
No. It energises the incoming supply line and can electrocute utility workers, and it is illegal in most places. A generator feeding house circuits needs a transfer switch installed by a qualified electrician.